SAFE-T-THERM® LC 25

SAFE-T-THERM® LC 25 Heat Transfer Fluid is an inhibited propylene glycol formulation specifically designed for liquid cooling applications requiring low conductivity, reliable corrosion protection, and long-term thermal stability.

SAFE-T-THERM® LC 25 is commonly used in data centers, high-performance computing environments, industrial process cooling systems, and other closed-loop cooling applications requiring dependable thermal management and efficient heat transfer performance.

SAFE-T-THERM® LC 25 also includes an orange dye to assist with leak detection and system identification.

SAFE-T-THERM® LC 25 is available in concentrate and pre-diluted solutions and can be packaged and sold in pails, drums, totes, and bulk quantities to meet a wide range of customer and system requirements.

Frequently Asked Questions

SAFE-T-THERM® LC25 is a pre-mixed inhibited propylene glycol heat transfer fluid designed for data center cooling systems. It provides freeze protection, corrosion protection, and reliable thermal performance while eliminating the need for on-site mixing.

SAFE-T-THERM® LC25 is used in closed-loop cooling systems, chilled water systems, dry coolers, fluid coolers, heat exchangers, and other thermal management equipment that support data center operations.

Pre-mixed fluids eliminate dilution errors, ensure consistent fluid quality, reduce installation time, and help maintain reliable system performance. SAFE-T-THERM® LC25 arrives ready to use and contains deionized water and corrosion inhibitors.

Yes. SAFE-T-THERM® LC25 is designed for applications where cooling system reliability is essential. Its corrosion inhibitor package helps protect critical infrastructure and support long-term system performance.

SAFE-T-THERM® LC25 helps protect pumps, piping, valves, heat exchangers, coils, and other cooling system components from corrosion, scale formation, and freeze damage.

SAFE-T-THERM® LC25 contains approximately 25% inhibited propylene glycol and provides burst protection and freeze protection for many commercial and data center cooling applications. Specific protection levels should be verified based on system design and operating conditions.

Yes. SAFE-T-THERM® LC25 is commonly used in chilled water systems where freeze protection is required and cooling equipment may be exposed to low ambient temperatures.

Propylene glycol provides freeze protection while helping protect system components from corrosion. It is commonly used in data centers, commercial buildings, and industrial facilities requiring dependable thermal management.

Data center cooling fluids should be tested regularly to monitor glycol concentration, inhibitor levels, pH, reserve alkalinity, and overall fluid condition. Annual testing is recommended, with more frequent testing for critical systems. Contact us to discuss your specific testing requirements.

Yes. By helping prevent corrosion and scale formation, SAFE-T-THERM® LC25 can reduce maintenance requirements and help extend equipment life.

For most data center cooling systems typically recommend a 25% glycol concentration to provide freeze protection while maintaining efficient heat transfer and system performance. SAFE-T-THERM® LC25 is a convenient 25% glycol pre-mixed solution designed to meet these common requirements, eliminating the need for on-site mixing and helping ensure consistent fluid quality throughout the system.

However, the required glycol concentration may vary depending on the equipment manufacturer, system design, operating temperatures, and site-specific freeze protection requirements. Always consult the equipment specifications and project requirements when selecting the appropriate glycol concentration.

Yes. SAFE-T-THERM® LC25 contains corrosion inhibitors designed to protect common cooling system metals, including steel, copper, brass, cast iron, and aluminum.

Fluid life depends on operating conditions, maintenance practices, and contamination levels. Routine testing and proper system maintenance can significantly extend fluid life.

Yes. SAFE-T-THERM® LC25 is available in pails, drums, totes, and bulk quantities to support data center construction, expansion, and maintenance projects.

System Volume Calculator

Inches
Feet
Total System Volume

Concentration Adjustment Calculator

%
%
Gallons
Gallons to be removed from system
Gallons of water to be added to system
Gallons of concentrate to be added to system

Request a Quote